Rms-technologies R325P DRIVER Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Software Rms-technologies R325P DRIVER. RMS Technologies R325P DRIVER User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
R325PE Single Axis Driver
with Indexer and Encoder Reader
User Manual
And Commands Guide
Version 1.01
RMS Technologies
2533 N. Carson St. #4698, Carson City, NV 89706-0147
RMS Technologies Page 1 Version 1.01
R325P Single Axis Driver Manual 5/29/2013
Vista de página 0
1 2 3 4 5 6 ... 29 30

Resumo do Conteúdo

Página 1 - R325PE Single Axis Driver

R325PE Single Axis Driver with Indexer and Encoder Reader User Manual And Commands Guide Version 1.01 RMS Technologies 2533 N. Carson St. #4

Página 2

Figure 6.1 Using the R325P with more than 5V You can choose to supply the optos with the R325P’s internal 5V supply by jumping pins 1 to 4. But

Página 3 - Updated enable/disable pin

Configure the R325P using the DIP Switch R325P DIP Switch Settings Run Current Function SW1 SW2 SW3 SW4 0.3A ON ON ON ON 0.4A OFF ON ON ON 0.5A ON O

Página 4 - Table of Contents

Communicating with the R325PE Step 1: Move all dipswitches to the OFF position. Place jumper on Pins 1 & 2. Inage 6.3 1. Connect P1 to PC via

Página 5 - 2. ELECTRICAL SPECIFICATIONS

USB485 Converter Card Figure 6.3 7. COMMAND TABLES The R325PE can also be used as an indexer with closed loop controls. Basic controller commands c

Página 6 - 4. MECHANICAL SPECIFICATIONS

General Operation Commands Function Query/Command Code Value Minimum Maximum Default Absolute Position C AP Numeric -2,147,483,646 2,147,483,647 - Cu

Página 7

8. COMMANDS Protocol Syntax Command Format: #<Address><Command><value><CR><LF> Example: #ACP1000<CR><LF&g

Página 8 - 6. CONNECTION SPECIFICATIONS

Table 8.1 – List of Commands Command (Case Sensitive) Operand Example Description HOMING & POSITIONING HA 0 = Forward 1 = Reverse #AHA1 Motor

Página 9 - Connecting the Motor

Command (Case Sensitive) Operand Example Description VELOCITY & ACCELERATION (cont.) AP +/–2,147,483,646 #AAP1000 Moves to the 1000th position.

Página 10

Command (Case Sensitive) Operand Example Description VELOCITY & ACCELERATION (cont.) SB - #ASB Moves one step back Step Back - Command Only - M

Página 11 - R325P DIP Switch Settings

Command (Case Sensitive) Operand Example Description SETTING CURRENT HI 0-3000 #AHI300 Sets the Hold Current to 300mA (0.3A) Hold Current - Comman

Página 12 - RS485-232 Converter Card

Thank you for purchasing the R325PE Single-Axis Driver with Indexer. This product is warranted to be free of manufacturing defects for one (1) year f

Página 13 - 7. COMMAND TABLES

Command (Case Sensitive) Operand Example Description SD - #ASD Saves data Save Data - Command Only - This command causes a set of parameter values

Página 14 - Encoder Count

Command (Case Sensitive) Operand Example Description QUERY COMMANDS FR - #AFR Firmware Revision - Query Only - Returns 3 digit part code followed b

Página 15 - 8. COMMANDS

Command (Case Sensitive) Operand Example Description ENCODER VERSION COMMANDS EM 1, 2 #AEM2 Sets the Encoder Mode to 2 Encoder Mode – Command or Q

Página 16

ER 0 - 16777215 #AER *AER5 Error Read – Query Only - Returns the current Encoder Error value. If the product of Encoder Lines and Encoder mode is l

Página 17

9. Troubleshooting R325P is not functioning correctly Try putting the R325P into TEST mode by placing a jumper on Pins 3 & 4 of J1 as shown bel

Página 18

10. Appendix A: Recommended Cable Recommended Cable Configurations: DC Supply to Driver Cable length, wire gauge and power conditioning devices play

Página 19

NOTE: These recommendations will provide optimal protection against EMI and RFI. The actual cable type, wire gauge, shield type and filtering devices

Página 20

Recommended Cable Configurations: Driver to Motor Cable length, wire gauge and power conditioning devices play a major role in the performance of you

Página 21

* 0.5 MH is a typical starting point for the Common Mode Line Filters. By increasing or decreasing the value of L you can set the drain current to a m

Página 22

11. Appendix B: PF Value For applications requiring ultimate smoothness of motion and extreme accuracy, the R325P driver can be programmed via RS485

Página 23 - Motion Profile Commands

R325PE User Manual Product: R325PE Version: 1.01 Date: 5/29/2013 Version History Version Date Description of Changes 1.00 01/31/2013 New User

Página 24 - 9. Troubleshooting

• PF value 3 • Slow speeds • Bad waveform • PF value 1 • Fast speeds • Bad waveform RMS Technologies Page 30 Version 1.01 R325PE Sin

Página 25

Table of Contents 1. FEATURES... 5 2. ELECTRICAL SPECIFICATI

Página 26

1. FEATURES • Single Axis Driver with indexer for Bipolar step motors • Encoder readout function available • Operates from +12 to 48 VDC • Phase

Página 27

3. OPERATING SPECIFICATIONS Maximum Step Frequency: 2.5 MHz Operating Temperature: Low end – 0° C High end – Dependent on case temperature, bra

Página 28

5. PIN ASSIGNMENTS Mating Connectors P1 AMP 640441-3 P2 AMP 640441-5 P3 Phoenix 1803675 P1 – RS485 bus Interface P1 Configurati

Página 29 - 11. Appendix B: PF Value

CAUTION: Connecting Motor phases (A, A Bar, B, B Bar) to the incorrect location while the R325P is powered will cause the board to burn. Be sure to i

Página 30

Pin 6: Phase A Motor Connection Pin 7: Phase A Motor Connection Pin 8: Phase B Motor Connection Pin 9: Phase B Motor Connection CAUTION: Connecti

Comentários a estes Manuais